BNQLF - B & B 1495

Product Identification

Product ID:B & B 1495
MSDS Date:03/04/1987
FSC:7930
NIIN:00N029261
MSDS Number: BNQLF

Responsible Party
B & B CHEMICAL CO INC
875 WEST 20TH ST
HIALEAH, FL 33010
US

Emergency Phone: 305-888-5247

Info Phone: 305-888-5247

Cage: EO030

Contractor
B & B TRITECH, INC.
HIALEAH, FL 33010-2310 US

Telephone: 305-888-5247

Cage: 21361

Ingredients

METHANE, DICHLORO-; (DICHLOROMETHANE) (METHYLENE CHLORIDE)

CAS: 75-09-2

RTECS: PA8050000

OSHA PEL 500 PPM;1000 PPM, C

ACGIH TLV: 50 PPM

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:INHALATION: OVEREXPOSURE MAY CAUSE
DIZZINESS, HEADACHE, NAUSEA, CENTRAL NERVOUS SYSTEM DEPRESSION.
ELEVATED CARBOXY-HEMOGLOBIN LEVELS MAY CONTRIBUTE TO STRESS ON
CARDIOVASCULAR SYSTEM. LIVER, KIDNEY D AMAGE. SKIN: OVEREXPOSURE
MAY CAUSE IRRITATION, DEFATTING OF SKIN, DERMATITIS. EYES:
OVEREXPOSURE MAY (EFTS OF OVEREXP)
Explanation of Carcinogenicity:DICHLOROMETHANE: IARC GRP 2B, NTP
ANTICIPATED TO BE A CARCINOGEN, ACGIH GRP A2.
Effects of Overexposure:HLTH HAZ: CAUSE IRRIT. CHLOROCARBON MATERIALS
HAVE PRODUCED SENSITIZATION OF MYOCARDIUM TO EPINEPHRINE IN
LABORATORY ANIMALS & COULD HAVE SIMILAR EFFECT IN HUMANS.
ADRENOMIMETICS (E.G., EPINEPHRINE) M AY BE CONTRAINDICATED EXCEPT
FOR LIFE-SUSTAINING USES IN HUMANS ACUTELY OR CHRONICALLY EXPOSED
TO CHLOROCARBONS .
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INGESTION: DO NOT INDUCE VOMIT. GET MEDICAL ATTENTION. SKIN:
FLUSH WITH SOAP AND WATER. EYE: FLUSH WITH PLENTY OF WATER FOR AT
LEAST 15 MINUTES. GET MEDICAL ATTENTION. INHALATION: REMOVE TO
FRESH AIR. IF NOT BREATHING, GIVE ARTIFICIAL RESPIRATION.

Fire Fighting

Flash Point Method:COC
Flash Point:NONE TO BOILING
Extinguishing Media:FOAM, CO2, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
AND FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:TOXIC AND ACIDIC VAPORS. THERMAL
DECOMPOSITION PRODUCTS MAY INCLUDE HCL & PHOSGENE .

Accidental Release

Spill Release Procedures:ABSORB WITH SAND OR INERT MATERIAL. PREVENT
SPREAD OR SPILL. USE INDUSTRIAL VACUUM. AVOID BRTHG VAPS, CONTACT
W/SKIN, EYES & OPEN FLAMES, SPARKS. AVOID CONTAM OF SURF H2O &
GROUND. DO NOT FLUSH TO SEW ER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN COOL, DRY, WELL VENTILATED
AREA. KEEP DRUMS CLOSED WHEN NOT IN USE. AVOID CONTACT WITH SKIN,
EYES AND CLOTHING. AVOID BREATHING VAPORS.
Other Precautions:NO SMOKING IN AREA OF USE. DO NOT USE IN GENERAL
VICINITY OF ARC WELDING, OPEN FLAMES OR HOT SURFACES. HEAT AND/OR
UV RADIATION MAY CAUSE FORMATION OF HCL AND/OR PHOSGENE .

Exposure Controls

Respiratory Protection:WHEN PERMISSIBLE EXPOSURE LIMIT MAY BE EXCEEDED
USE NIOSH/MSHA APPROVED AIR-PURIFYING RESPIRATORS OR NIOSH/MSHA
APPROVED SUPPLIED AIR RESPIRATORS FOR ORGANIC VAPORS IN ACCORDANCE
WITH OSHA 29 CFR 1910 .134.
Ventilation:LOCAL OR GENERAL EXHAUST.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:CHEMICAL BOOTS.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

Chemical Properties

HCC:T4
Boiling Pt:B.P. Text:100F,38C
Spec Gravity:1.32 (H2O=1)
Evaporation Rate & Reference:SLOWER THAN ETHER
Solubility in Water:INCOMPLETE
Appearance and Odor:LIQUID-SOLVENT ODOR.
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
OXIDIZERS-STRONG ALKALIES.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:HCL, PHOSGENE .

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE,
AND LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.